For the complete documentation index, see llms.txt. This page is also available as Markdown.

BRCS01V - UL

BRCS01V-U5/U6 - UL & IEC

Applies to: BRCS01V-U5/U6 Residual Current Sensor (UL 2231-2 (CCID20) and IEC 62955 / IEC 62752) | Last Updated: 2026-09-28

1. Introduction

The BRCS01V-U5/U6 is an AC/DC residual current sensor with two separate fault signal outputs – one Pin conforming to UL2231-2 (CCID20) and the other Pin conforming to IEC 62955 or IEC 62752. It can be used for built-in residual current protection system at AC charging stations.

  • Digital outputs of fault detection conforming to UL2231-2 (CCID20) and IEC 62955 / IEC 62752

  • Cost-effective solution of residual current detection for mode-2/3 EVSE

  • Fast response time facilitating a broad selection of switching devices

  • Accurate measurement and optimization against nuisance tripping


2. Technical Data

#
Technical Specification
BRCS01V-U5
BRCS01V-U6

101

Rated current in monitoring circuit (1phase/3phase)

80A / 40A

80A / 40A

102

Rated frequency in monitoring circuit

60Hz

60Hz

103

Rated impulse withstand voltage in monitoring circuit

6kV

6kV

104

Over-voltage category in monitoring circuit

III

III

201

Rated operating voltage in control circuit, VccV_{cc}

5VDC ± 3%

5VDC ± 3%

202

Power consumption

< 500mW

< 500mW

203

Pin 1 – Vcc for 5V

+5VDC

+5VDC

204

Pin 2 – Trip signal: X20-UL2231 (CCID20)

Digital output

Digital output

205

Pin 3 – GND

GND

GND

206

Pin 4 – Trip signal: X6-IEC62955 (RDC-MD) or X30-IEC62752 (IC-CPD)

Digital output (RDC-MD)

Digital output (IC-CPD)

207

Pin 5 – Test signal

Digital input

Digital input

301

Rated DC residual operating current IΔdcI_{\Delta dc} (IEC 62955)

6mA

6mA

302

Rated DC residual non-operating current IΔndcI_{\Delta ndc} (IEC 62955)

3mA

3mA

303

Rated AC residual operating current IΔnI_{\Delta n} (UL2231-2)

20mA

20mA

304

Rated AC residual non-operating current IΔncI_{\Delta nc} (UL2231-2)

15mA

15mA

305

Rated AC residual operating current IΔnI_{\Delta n} (IEC 62752)

-

30mA

306

Rated AC residual non-operating current IΔncI_{\Delta nc} (IEC 62752)

-

15mA

307

Electrical endurance

20,000

20,000

308

Rated operating temperature

-40~85 ℃

-40~85 ℃

309

Pollution degree

2

2


3. Residual Current Detection Characteristics

PIN 4 (X6/X30 Output) - IEC 62955 / IEC 62752

Operating Current

#
Operating Current
PIN 4 (X6) @BRCS01V-U5
PIN 4 (X30) @BRCS01V-U6

401

Smooth DC

4.0~6.0 mA

4.0~6.0 mA

402

DC rectified from 2 phases

4.0~7.0 mA

4.0~7.0 mA

403

DC rectified from 3 phases

4.0~6.2 mA

4.0~6.2 mA

404

Sinewave AC

-

22.0~28.0 mA

405

A0 pulsating DC

-

10.5~42.0 mA

406

A90 pulsating DC

-

7.5~42.0 mA

407

A135 pulsating DC

-

3.3~42.0 mA

Operating Time

#
Response time
PIN 4 (X6) @BRCS01V-U5
PIN 4 (X30) @BRCS01V-U6

501

Smooth DC 6mA

≤ 500 ms

≤ 500 ms

502

Smooth DC 60mA

≤ 200 ms

≤ 200 ms

503

Smooth DC 200mA

≤ 70 ms

≤ 70 ms

504

Smooth DC 300mA

-

≤ 20 ms

505

DC rectified from 2 phases 60mA

≤ 200 ms

≤ 200 ms

506

DC rectified from 2 phases 200mA

≤ 70 ms

≤ 70 ms

507

DC rectified from 2 phases 300mA

-

≤ 20 ms

508

DC rectified from 3 phases 60mA

≤ 200 ms

≤ 200 ms

509

DC rectified from 3 phases 200mA

≤ 70 ms

≤ 70 ms

510

DC rectified from 3 phases 300mA

-

≤ 20 ms

511

AC 30mA

> 10000 ms

≤ 80 ms

512

AC 60mA

> 300 ms

≤ 60 ms

513

AC 150mA

> 80 ms

≤ 20 ms

514

AC 5A

> 80 ms

≤ 20 ms

PIN 2 (X20 Output) - UL2231-2 (CCID-20)

Operating Current

#
Operating Current
PIN 2 (X20) @BRCS01V-U5/U6

601

60Hz sinewave AC

15.0~20.0 mA

602

150Hz sinewave AC

15.0~34.5 mA

603

400Hz sinewave AC

15.0~69.6 mA

604

Smooth DC

20.0~56.0 mA

Operating Time

#
Response time
PIN 2 (X20) @BRCS01V-U5/U6

701

20mA AC residual current (60Hz)

≤ 500 ms

702

100mA AC residual current (60Hz)

≤ 20 ms

703

264mA AC residual current (60Hz)

≤ 15 ms

704

56mA smooth DC residual current

≤ 40 ms

705

100mA smooth DC residual current

≤ 20 ms


4. Application Notes

Typical application diagram

BRCS01V version EV charging controller

Additional information

  • Vcc Pin (Power supply pin): The power supply voltage range to the sensor is 4.85 - 5.15 VDC, and the power ripple is not higher than 150mV. Ferrite beads and filter capacitors are suggested to be placed close to the Vcc pin. In addition, a LDO - such as LP2985A-50DBV - is strongly recommended to be used at the charging controller side.

  • Trip Pins (Fault signal output pin): When residual current in the circuit exceeds the threshold, the output level changes from low to high. Suggest adding ferrite beads and filter capacitors close to this pin. A direct connection of Pin 2/4 to switching devices - such as relays or contactors - is NOT allowed. The trip signal of Pin 2/4 is suggested to be monitored by the charging controller MCU.

  • TEST Pin (Self-test input pin): Before starting every charging, this pin is used to perform a simulated test to verify whether the sensor functions correctly.

Self-test time chart

  • A self-test excluding offset calibration is activated if Pin 5 - Test is connected to GND for a period of 40ms to 130ms.

  • A self-test including offset calibration is activated if Pin 5 - Test is connected to GND for a period of 150ms to 1000ms. (Note: t1t_1 is the response time for internally generated test current.)

Offset calibration time chart

An explicit offset calibration excluding self-test cycle is activated if Pin 5 - Test is connected to GND for a period of 2s to 3s. An offset calibration can be activated at regular intervals (such as start-up) or after the occur of certain critical events (such as short circuit).

⚠️ Attention: During the offset calibration, NO leakage current or any other current may flow through the device and the relays/contactors must be open. Also, the power supply voltage at Pin 1 Vcc must be stay at 5VDC ± 3%.

Switching recovery level

If the trip-level IΔTI_{\Delta T} is accomplished the output will change their state from low-level to high level. Depending on the existence of the residual current IΔI_{\Delta}, the output will remain in this state until IΔI_{\Delta} falls below the threshold IΔRI_{\Delta R}.

  • X20 Pin (CCID20): Typical values of IΔTI_{\Delta T} DC 26mA & AC 17.5mA; Typical value of IΔRI_{\Delta R} is 75%.

  • X30 Pin (IEC 62752): Typical values of IΔTI_{\Delta T} DC 5mA & AC 24mA; Typical value of IΔRI_{\Delta R} is 75%.

  • X6 Pin (IEC 62955): Typical values of IΔTI_{\Delta T} DC 5mA; Typical value of IΔRI_{\Delta R} is 75%.


5. Mechanical outline

BRCS01V-U5/U6-S:

Model
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5

BRCS01V-U5-S1

5V DC

AC & DC fault (UL2231(CCID20))

GND

DC fault (IEC 62955)

Test

BRCS01V-U6-S1

5V DC

AC & DC fault (UL2231(CCID20))

GND

AC & DC fault (IEC 62752)

Test


6. Ordering information

#
Order Number
Description

1

BRCS01V-U5-S1

BRCS01V Residual Current Sensor, 5V DC UL2231-2(CCID20) & IEC62955

2

BRCS01V-U6-S1

BRCS01V Residual Current Sensor, 5V DC UL2231-2(CCID20) & IEC62752


7. Additional Notes

🛑 ESD Warning: The sensor is susceptible to be damaged from an ESD event and the personnel should be grounded when handling it.

  • Do NOT allow strong static electricity near the sensor, because static electricity can cause damage to the ICs inside the sensor. Take static electricity precautions when handling.

  • Do NOT exceed 260°C for 10 seconds when soldering the sensors of PCB-mounting versions. This is the maximum heat resistance grade of these sensors.

  • Do NOT drop the sensor or apply any other mechanical stress to the sensor, as such stresses may change performance characteristics.

  • Please place the sensor with an appropriate distance from components that can generate high magnetic fields, such as relays or contactors, to ensure accurate residual current detection.

Last updated