BLE Plaintext API
SPM/SDM Meter Plaintext BLE API
Over Bluetooth Low Energy you can talk to the meter's communication module to: provision 2.4 GHz Wi-Fi, read electrical readings and network status, configure MQTT / UDP / Modbus, switch LAN protocols on or off, and trigger locate / restart / OTA.
The protocol is plaintext UTF-8 JSON. This document is written for system integrators, DIY developers and AI coding assistants.
How the docs are split: this page covers only the transport layer of the plaintext channel (UUIDs, unlock, request/response matching, disconnect and reconnect) plus app-development rules. Provisioning commands, device commands, snapshot fields and business error codes are in the Business Command Reference (shared by plaintext and secured), maintained once for both channels.
1. Quick start (5 minutes)
Minimal loop: connect → subscribe to notifications → unlock → provision Wi-Fi → read the IP to confirm.
Advertised name
<model>-<serial>, e.g. SDM01_3PN-10304B0D7760; filter by prefix SDM / SPM
Service
0xA002
Write (commands)
0xC303
Read (snapshot)
0xC304
Notify (responses)
0xC305
Factory BLE password
1234 (max 16 characters)
Wi-Fi
2.4 GHz only
1.1 Try a tool first (recommended)
If you do not want to write code yet, connect to a meter once with the Chrome page or the Windows tool in Section 10 to see the flow and the responses.
1.2 Minimal runnable example for Chrome / Edge
It already includes: serialized sending, event matching (including the pas special case), unlock, provisioning, and polling IP. requestDevice must be triggered by a user click.
2. Build your own app with AI
Give the AI the whole of this page together with the prompt below.
After the AI generates code, self-test it with the acceptance checklist (9.3).
3. Overview and scope
3.1 What you can do
Discover and connect to the device
Unlock the current GATT connection
Send the Wi-Fi SSID and password
Read IP / signal strength / electrical readings
Configure MQTT, UDP and Modbus 485, switch LAN protocols, check / run firmware upgrades
3.2 Does this document apply?
Use this document if both are true:
The advertised name starts with
SDM/SPM;The GATT service
A002is present.
Do not use this document if:
The service is A003 and packets contain nonce / ct / tag
Encrypted channel, out of scope
You need to control a relay / breaker
This document has no switching commands
The device has no Wi-Fi
There is no provisioning path described here
You only use HTTP / MQTT, not BLE
See the API document of that channel
3.3 Model differences
Models do not support exactly the same commands. When a command is not supported the device returns a failure: some answer unsupported, others unknow cmd (1015). For example, models without WebSocket have no setInterval; models without LAN TLS have no enablehttps. Clients must handle ok / msg and must not assume that every device has every command.
Identify the product by the advertised name and by TP and SN in the read characteristic, not by what is printed on the enclosure.
4. GATT and session
4.1 UUIDs
Case-insensitive.
Primary service
0xA002
0000A002-0000-1000-8000-00805F9B34FB
Write (client → meter)
0xC303
0000C303-0000-1000-8000-00805F9B34FB
Read (status snapshot)
0xC304
0000C304-0000-1000-8000-00805F9B34FB
Notify (meter → client)
0xC305
0000C305-0000-1000-8000-00805F9B34FB
4.2 Transport rules
Encoding is UTF-8 JSON, no BOM. One command = one Write; one response = one Notify.
Subscribe to
C305before the first command, otherwise the device looks unresponsive.Commands must be serialized: write one, wait for its response, then write the next. Do not interleave
C304polling with command writes.Only one BLE connection is supported at a time. While connected the device stops advertising, so other clients cannot see it.
MTU: the JSON you write must fit in a single Write (the device accepts about 512 bytes at most; longer input returns
payload too large). The device sends each response as one notification and does no application-level fragmentation, so a response cannot exceedMTU - 3bytes. Measured sizes:modelabout 200 bytes,mqttdataabout 200 bytes, andgetwifilist(up to 10 networks) can exceed 300 bytes. If the MTU stays at the default 23, these responses will be truncated and show up as JSON parse errors. The device requests an MTU of 517; on Windows (bleak) 527 was negotiated in testing; on Android callrequestMtu(517)after connecting; Web Bluetooth negotiates it in the browser.Do not use
A003,C313/C314/C315, and do not sendnonce/ct/tag.
4.3 Unlock
All business JSON on the write characteristic requires unlocking first. Scanning, connecting and subscribing to notifications do not need a password.
Success:
{"ok":true,"msg":"Password Correct","event":"pass"}Wrong password:
Password Error,code1003Business command sent while locked:
Please unlock,code1002,eventispas
Meaning of continue:true: within the same BLE connection, later commands do not need pas, and you may read GATT C304 repeatedly. Your app should always send continue:true. The session ends on disconnect or device restart and you must unlock again.
pass can also carry newpas (≤16) to change the password at the same time, or auth (≤40) for phone binding. Normal integrations do not need them.
4.4 Requests and responses
Request (write to C303):
cmd
string
Required in every request
pas
string
Required only for cmd=pass
continue
boolean
Used with pass / read, always true
others
—
See each command
Response (notification on C305):
ok
boolean
Whether the request succeeded
msg
string
English text; compare it verbatim
event
string
Usually equals the request's cmd; pas when locked
code
integer
Present only on failure
d
object
Only query commands carry data
Matching rule (copy it as is):
event == "pas" means the gate was not passed: unlock again, do not keep waiting for the original command.
Suggested timeouts: 8–15 s for normal commands, 20 s for wifi, 25 s for checkota / startota.
4.5 Disconnect and reconnect
The GATT connection is persistent: the device does not close it because of inactivity, but moving away, interference or a device restart will drop it.
Which commands make the device drop GATT:
restart
Yes
The device restarts after responding
reset
Yes
Clears the configuration and restarts
mqtr
Yes
Saves the MQTT configuration and restarts
mqtt
No
Saves only, no restart
wifi
No
BLE stays connected after provisioning, so you can keep polling C304 for the IP
enablehttp / enablewebsocket / enablemodbustcp / enabletls / functionMap
No
Only saves the configuration and keeps BLE connected; we recommend sending one restart afterwards, see Business reference 3.3
startota
Usually no
If reboot is 1 the device restarts about 1 s after a successful upgrade; with an HTTPS URL and low memory it may save the URL and restart immediately
all other commands
No
Reconnect algorithm (implement as written):
5. Wi-Fi provisioning
A meter usually leaves the factory without router credentials. The phone connects over BLE first, then sends the 2.4 GHz SSID and the router password. Once it succeeds the meter joins the LAN, and HTTP / MQTT / Modbus TCP and so on become usable.
Everything is written to C303; responses come on C305.
5.1 User flow
Turn on Bluetooth and stand close to the meter.
model-serialappears in the list; connect and enter the BLE password (factory1234).Optional: have the meter scan nearby Wi-Fi networks and pick an SSID.
Enter the router password (not the BLE password) and tap "Send to meter".
After about ten seconds read the status; success is
IPbecoming192.168.x.x.
5.2 Protocol steps
A. Unlock See 4.3.
B–D. Scan, send SSID / password, confirm online, UI copy: the business-layer commands are identical to the secured channel; see Business Command Reference, Section 2.
The whole flow:
6. Command reference
Write to C303 after unlock. event equals cmd by default.
6.1 Session (plaintext channel only)
cmd
Request
Success msg
Common failures
pass
{"cmd":"pass","pas":"1234","continue":true}
Password Correct
1003
blepassword
{"cmd":"blepassword","old":"1234","new":"654321"}
Password yes
Wrong old password 1026; new password too long 1002 (check msg)
read
{"cmd":"read","continue":true}
ready
resetauth
{"cmd":"resetauth"}
Only needed when phone binding is enabled
Change the default password with blepassword after installation.
6.2 Business commands
Wi-Fi, restart / location / zero / reset / deviceName, model / getFunctionMap / mqttdata / udpdata, LAN switches, MQTT, Modbus 485, UDP and OTA are documented once for both channels: Business Command Reference, Section 3. Command index: Section 4.
Plaintext-specific notes: after a successful restart / reset / mqtr the device drops the GATT link; reconnect per 4.5 and pass again. After changing LAN switches, send one restart.
6.3 Command index (plaintext-only part)
pass, blepassword, read, resetauth (business commands: see the shared command index)
Do not use command or field names that appear in no document.
7. Read characteristic C304: IP and electrical readings
The IP and electrical snapshot is obtained with a GATT Read of C304; do not mix it with notifications.
After pass + continue:true you can simply read repeatedly. If unsure, first send {"cmd":"read","continue":true} and read after you receive ready. When locked, a Read returns {"ok":false,"msg":"Please unlock","code":1002,"event":"read"}.
Numeric readings are mostly decimal strings, not JSON numbers; convert them yourself.
7.1 What you read
The JSON fields you read back (IP / RSSI / FW / SN / TP, electrical keys, units, examples) are the same on both channels; see Business Command Reference, Section 5.
8. Error codes
On failure the notification or the read characteristic is JSON: ok=false, an integer code and an English msg. Success packets have no code.
For configuration failures the BLE code = 1000 + sub-code, so some numbers overlap with fixed codes (especially 1002–1005). Rely on msg; use code only as a hint.
8.1 Common error codes
code
msg
Meaning / action
1000
auth error
Phone-binding string mismatch. Check auth or use resetauth
1001
not authenticated
Binding authentication not completed
1002
Please unlock
Locked. Send pass first. The same code can also be Error password length!
1003
Password Error
Wrong BLE password. Factory default is 1234
1004
No cmd
JSON has no cmd. The same code can also be bad value (invalid number)
1005
No data received
Required parameter missing. The same code can also be unsupported (this model lacks the command)
1026
Old Password Error
Wrong old password in blepassword
1050
payload too large
Write too long, shorten the JSON
Business-layer codes (1014–1044 etc., including Wi-Fi / MQTT / UDP) are in Business Command Reference, Section 6; less common codes: Appendix A.
8.2 Cases without a code
msg is illegal cmd / unsupported
This model does not have the command
The client gets no response (timeout)
C305 not subscribed, device restarted, too far away, or responses truncated by a small MTU
The notification is not JSON
Log it and ignore it, do not crash
9. Developer checklist
9.1 Hard rules for apps / AI
Use only
A002 / C303 / C304 / C305.Write UTF-8 JSON with Write With Response; subscribe to
C305first after connecting.Send
pass+continue:truefirst.Serialize commands; match by
event, mind thepasspecial case.Provision only with
cmd=wifi; afterwards pollIPinC304.After restart-type commands, reconnect and unlock again per 4.5.
Do not use commands or fields that are not in this document.
9.2 Suggested module split
scan (name filter) → connect (MTU + notify) → unlock → rpc (write JSON, serialized, wait for event) → provisionWifi → scanWifi (wifiscan + poll getwifilist) → readSnapshot (GATT Read + JSON.parse) → reconnect.
9.3 Acceptance checklist
9.4 Platform notes
Android
Call requestMtu(517) after connecting; on status 133 disconnect, wait, then reconnect; keep only one GATT connection at a time
iOS
The MAC address is not available; use the advertised name prefix + service UUID; Web Bluetooth is not available, use Core Bluetooth
Windows
Use bleak in Python; the first scan may prompt for Bluetooth permission
Browser
Chrome / Edge only; needs HTTPS or 127.0.0.1; Firefox and Safari are not supported
10. Demo tools
Both tools use exactly the same protocol as this document. We suggest confirming the meter's behavior with a tool before writing your own app. Both tools have a Chinese / English switch; the JSON they exchange is identical to what is described here and is never translated.
Hosting: the official hosted web page and the Windows tool download address follow the publishing channel and will be added here once released. Tool sources are in this repository: tools/ble-plaintext/ (see tools/README.en.md).
10.1 Chrome / Edge web page
Use Chrome or Edge.
file://pages are often blocked from using Bluetooth, so use an HTTPS page, or runpy -3 -m http.server 8765intools/ble-plaintextand openhttp://127.0.0.1:8765/web-ble-console.html.Click "Select device and connect", choose the meter in the system dialog; it unlocks automatically (the password box defaults to
1234).Enter the SSID and router password, click "Send Wi-Fi", then click "Read IP / readings".
Tabs on the right: Log, Readings, Comm config (Modbus RTU / MQTT / UDP), Commands / abbreviations.
10.2 Windows GUI tool
Requires PyQt6 and bleak. It provides: scan / connect / unlock, a Wi-Fi list (double-click to fill the SSID), a readings table, a communication-config page, a command / abbreviation cheat sheet, and custom JSON. With "reconnect automatically after device restart" ticked, restart-type commands need no manual reconnect.
10.3 Which one to use
Demonstrating provisioning, Chrome available
Web page
Factory PC with Python
Windows tool
Writing an iOS app
Follow the JSON in this document and use Core Bluetooth
Writing an Android app
Verify the protocol with the web page first, then write the native app
11. Security notes
The BLE password limits "whether you can change the configuration once connected"; it is not over-the-air encryption. The plaintext channel has no link-layer encryption, so anyone near the device can capture the traffic. The Wi-Fi password is also sent in plaintext during provisioning.
Recommendations:
After installation, change the default password
1234withblepassword;Do not treat BLE as a remote secure channel; send confidential data over HTTPS / MQTTS after the device is online;
The plaintext channel does not close GATT automatically when nobody is connected for a long time, so consider physical security for on-site deployments.