BLE Business Command Reference
BLE Business Command Reference (shared by plaintext and secured channels)
This page is the single source of truth for the business JSON: provisioning and device commands, snapshot fields, and business error codes. After the transport layer is removed, the business JSON of both BLE channels is identical, so it is maintained only here. The transport layer (UUIDs, unlock / handshake, encrypted envelope, reconnect) lives in each channel document.
Basic / Basic+ (service A002)
Plaintext BLE API
this page
Lite / Pro (service A003)
Secured BLE API
this page
For system integrators, DIY developers and AI coding assistants. Command names, field names and device msg strings are kept in English exactly as the device returns them.
1. Conventions
1.1 Requests and responses
A request is one JSON object. cmd is required on every request; other fields depend on the command. Response:
ok
boolean
success or not
msg
string
English text, compare verbatim
event
string
normally equals the request cmd
code
integer
failures only, see Section 6
d
object
only on query commands
Match rule: a reply is yours and successful when resp.event == cmd and resp.ok == true. Each channel has one kind of "reply that is not for your command" you must recognise: event == "pas" on plaintext (not unlocked) and event == "secure" on secured (envelope-layer failure). See each channel document for handling.
Commands are strictly serial: write one, wait for its reply, then write the next. Suggested timeouts: 8–15 s for most commands; 20 s for wifi; 25 s for checkota / startota.
1.2 Differences between the two channels (this is all of them)
Item
Plaintext BLE (A002)
Secured BLE (A003)
Gate
cmd=pass + BLE password
ble-crypto-* handshake (PIN + SN)
Write
JSON written directly to C303
same JSON encrypted into {nonce,ct,tag} and written to C313
Reply
C305 notification, plaintext
C315 notification, envelope; after decryption identical to plaintext
Snapshot read
C304 GATT Read, plaintext
C314 GATT Read, may be an envelope; decrypt, then parse
Trigger snapshot
{"cmd":"read","continue":true}
{"cmd":"read"}
Channel-only commands
pass, blepassword, resetauth
ble-crypto-ver, ble-crypto-reset, ble-crypto-jpake-round1, ble-crypto-jpake-round2, ble-crypto-session-nonce
After reboot / disconnect
pass again
step=2: resume with LTK; otherwise J-PAKE again
Apart from this table, every command, field, value and error code on this page is the same for both channels.
1.3 Model differences
Models do not support exactly the same commands; an unsupported command fails — some reply unsupported, some unknow cmd (1015). For example, a model without WebSocket has no setInterval; a model without LAN TLS has no enablehttps. Clients must act on ok / msg and must not assume every device has every command. Product identity comes from the advertised name and TP / SN in the snapshot.
2. Wi-Fi provisioning (business commands)
A meter usually has no router credentials out of the box. First complete unlock (plaintext) or the secure handshake (secured) for your channel, then send the 2.4 GHz SSID and router password. Once joined, HTTP / MQTT / Modbus TCP etc. become available.
The commands below are identical on both channels (on the secured channel, wrap the JSON in the encrypted envelope first).
2.1 (Optional) scan for nearby Wi-Fi
Success: msg=scan started. If a scan is already running: scan busy / 1043, try again in a few seconds. Wait 3–8 seconds, then:
d.list: comma-separated, each item is ssid|rssi (integer dBm, closer to 0 is stronger), at most 10 items, sorted by strength, duplicate names keep only the strongest. If not ready: scan not ready / 1044, wait 2–3 s and retry.
2.2 Send SSID and password
ssid
Required, ≤ 64
pass
≤ 64; an empty string for open networks
enableble
Optional boolean. Meaningful only on firmware with secured BLE (Lite / Pro): when on, the device keeps the application GATT service and the service UUID in advertising after Wi-Fi is connected; when off, the device withdraws the application GATT once Wi-Fi is up. Persisted across power cycles, cleared by factory reset; omit to keep the stored value
enablehttps
Optional boolean. Pro only: persistently enables LAN HTTPS (443) after provisioning, effective after a restart; omit to keep the stored value; ignored on non-Pro. On Pro, when this is on, periodic UDP reports use an AES-CCM wrapped JSON (ct / tag / counter); otherwise UDP stays plaintext JSON
Success: {"ok":true,"msg":"WIFI successfully","event":"wifi"}. This means the meter accepted the credentials and started connecting to the router; it does not mean an IP has been obtained yet. Missing fields: 1018; too long: 1019.
2.3 Confirm it is online
On the plaintext channel send {"cmd":"read","continue":true}. After ok=true, GATT Read the snapshot characteristic (C304 on plaintext; C314 on secured, decrypt first) and look at IP:
IP
Meaning
An IPv4 address such as 192.168.x.x
Online, provisioning succeeded
-1
Just sent, state unknown
0
Idle
1
SSID not found (wrong name, not 2.4 GHz, too far away)
3
Associated (normally becomes an IPv4 address very soon)
4 / 5 / 6
Failed / lost / disconnected (a wrong password is the most common cause)
After provisioning, read every 2 s for about 30 s at most.
2.4 Suggested UI copy
Title "Connect meter to Wi-Fi"; SSID field "2.4 GHz network name"; password field "Router password (not the BLE password / PIN)"; primary button "Send to meter"; secondary button "Scan nearby Wi-Fi" (only after unlock / secure handshake).
3. Command reference
Send once the channel is ready (plaintext: pass done; secured: step=3). event equals cmd by default.
3.1 Device control
cmd
Request
Success msg
Note
restart
{"cmd":"restart"}
restart received
GATT then drops; reconnect per plaintext 4.5 / secured 4.10
location
{"cmd":"location"}
location received
The LED blinks at about 4 Hz for 15 s so you can find the meter on site
zero
{"cmd":"zero"}
zero received
Clears accumulated energy, cannot be undone
reset
{"cmd":"reset"}
reset received
Clears the configuration and restarts
deviceName
{"cmd":"deviceName","name":"RoomMeter01"}
deviceName yes
name ≤ 30; longer returns 1027
commonmode
{"cmd":"commonmode","value":0}
commonmode yes
Sets the message reporting format: 0 = BT format, 1 = generic format
3.2 Queries
model, configuration snapshot:
See Appendix C for the short keys. The set of keys differs slightly between models: handle them by "does the key exist".
getFunctionMap, enabled communication features:
32896 = 32768 + 128, meaning Modbus TCP (bit 15) and HTTP (bit 7) are enabled. See Appendix B for the bits.
mqttdata:
TP/TC/TR/TM are the four topics (the defaults contain the model and serial number); MU / MPS are the MQTT credentials. The response above is from a real device with MQTT not enabled, and it has no MF key; only devices with MQTT enabled add MF, for example "MF":0. Handle it by "does the key exist".
MF (when MQTT is enabled): -4 timeout, -3 connection lost, -2 TCP/TLS failure, -1 disconnected, 0 connected, 1 protocol rejected, 2 ClientId rejected, 3 broker unavailable, 4 bad credentials, 5 not authorized. Some firmware returns -1 when MQTT is not enabled, others omit MF entirely, so also check whether MQTT has been configured. Note: MF in model is a boolean; do not mix it up with the numeric status code here.
udpdata:
3.3 LAN protocol switches
cmd
Purpose
Success msg
enablehttp
Plain HTTP on :80. enable omitted or true = on, false = off
http yes / http off
enablewebsocket
WebSocket; optional enableTLS
websocket yes
enablemodbustcp
Modbus TCP
modbus tcp yes
enabletls
TLS feature bit
tls yes
enablehttps
LAN HTTPS (some models only)
https yes / https off
These commands only save the configuration. They do not drop BLE and do not restart the device by themselves. The device has limited memory, and toggling communication channels repeatedly fragments it, so:
After changing the switches, send a single
{"cmd":"restart"}and reconnect per plaintext 4.5 / secured 4.10;After
enablehttpis turned on,:80only starts listening after a restart; turning it off stops it immediately;Do not toggle channels frequently at run time, and do not enable several memory-hungry channels at once (see
functionMap errorbelow).
Writing {"cmd":"functionMap","value":<integer>} directly overwrites the whole bitmap, and the number of LAN channels that can be on at the same time is limited; exceeding it returns functionMap error (1014). Normal apps should use the enable* commands above and not write functionMap directly.
3.4 MQTT
data = host|clientid|ssl|port|interval|username|password. ssl: 1 TLS, 0 plaintext. interval is in seconds; after saving it appears in model as MI in milliseconds. Success: MQTT successfully.
mqtt: saves only, no restart.mqtr: same parameters, saves and then restarts.Empty
data:Error mqtt data empty!/ 1021.
To use your own CA certificate for MQTT: send cafilestart first, then cafiledata in several chunks. You can skip this if you only do Wi-Fi provisioning.
3.5 Modbus 485, UDP, OTA
Success: modbus yes. parityStop: 0 = N81, 1 = E81, 2 = O81, 3 = N82 (no parity, 2 stop bits). The current 485 settings can be read from model.d.MAD, for example "5 / 9600 / N81" (address / baud rate / parity).
UDP targets (at most 5):
IpAddress: target IP;localUdpPort: target port (that is the field name, but it means the remote port).Frequency: optional, report period in seconds; the device converts it to milliseconds (UIinmodel) with a lower limit of 100 ms; if omitted the current period is kept. The period is global and shared by all UDP targets.Success:
UDP successfully. Sending the same IP + port again only updates the period. Adding a target automatically turns on the UDP feature bit (functionMap bit 13).If the IP is empty or the port is invalid, the device also returns
UDP full/ 1024, so do not read it literally as "full".Delete:
{"cmd":"deleteudp","IpAddress":"192.168.1.100","localUdpPort":9000}, successUDP deleted; if it does not existUDP not found/ 1025. Deleting a target does not turn off the UDP feature bit.List:
udpdata, see 3.2. Targets are ind.udp_dataas{"ip":"…","port":"…"}; with no targets it is an empty array.
OTA upgrade:
checkota
{"cmd":"checkota"}
Asks the server whether new firmware exists, without downloading. The device has to contact the server, so it took about 8 seconds to answer in testing; allow 25 s
otaprogress
{"cmd":"otaprogress"}
Query progress, read-only
startota
{"cmd":"startota"} or with url / reboot
Starts the upgrade and returns immediately; poll progress with otaprogress
checkota response (otastatus: 200 update available, 404 already up to date or version info invalid, 199 not enough device memory, anything else is a network / server error code):
otaprogress response (real device, no upgrade running):
otastatus
otastatusText
Meaning
-1
idle
No upgrade task (default after power-up)
0
success
Upgrade finished; it only counts as success when otaprogress is 100
1
write length insufficient
Firmware data incomplete
2
verify failed
Firmware verification failed
3
set boot partition failed
Switching boot partition failed
4
ota begin failed
Upgrade initialization failed
5
no ota partition available
No usable upgrade partition
6
ota running
Upgrade in progress
other
—
Network / HTTP error code during download
startota: url is optional and defaults to the address determined by checkota; reboot is optional (true / false / 1 / 0, default 1); with 0 the device does not restart after the upgrade and the client has to send restart itself. Success response: {"ok":true,"msg":"startota yes","event":"startota"}. The upgrade runs in the background on the device; do not cut the power while it runs.
WebSocket push interval:
setInterval / getInterval
Control only the WebSocket push interval (milliseconds, 100–86400000, usually 5000 by default); they do not change MQTT MI or UDP UI. Unsupported models fail: some answer unsupported, others (such as SDM01_3PN) answer unknow cmd / 1015. Treat both as a failure
4. Command index (for AI to scan)
Business commands (both channels):
read, wifi, wifiscan, getwifilist, restart, location, zero, reset, deviceName, commonmode, model, getFunctionMap, functionMap, enablehttp, enablehttps, enablewebsocket, enablemodbustcp, enabletls, setInterval, getInterval, mqtt, mqtr, topic1, topic2, mqttdata, cafilestart, cafiledata, modbus, getModbusTlsMuxSetupStatus, udp, deleteudp, udpdata, checkota, otaprogress, startota
Channel-only commands: plaintext pass, blepassword, resetauth (see the plaintext doc); secured ble-crypto-ver, ble-crypto-reset, ble-crypto-jpake-round1, ble-crypto-jpake-round2, ble-crypto-session-nonce (see the secured doc).
Do not use command or field names that are not listed here.
5. Snapshot read: IP and electrical readings
The electrical / IP snapshot is obtained with a GATT Read (C304 on plaintext, C314 on secured); do not mix it with notifications. Send the read command first (see 1.2), then Read after the ready reply.
On the secured channel the bytes read back may be an envelope {nonce,ct,tag}; the JSON below appears after decryption. On the plaintext channel, reading before unlock returns Please unlock (1002).
Most numeric readings are decimal strings, not JSON numbers; convert them yourself.
5.1 Common fields
IP
string
Online = IPv4; not online = a status code, see 2.3
RSSI
int
Downlink signal strength from router to meter (dBm)
FW
string
Firmware version
SN
string
Serial number
TP
int
Product type code
5.2 Electrical keys: parse by "does the key exist"
Do not hard-code single-phase / three-phase from TP. If VX / VY / VZ exist, parse as multi-phase; if V exists, parse as single-phase. A missing key means the model does not have that item.
Single-phase
V I P PF F FE RE
Three-phase
VX VY VZ, IX IY IZ, PX PY PZ, PFX PFY PFZ, F, FEX FEY FEZ, REX REY REZ
Two-channel
Same as three-phase but only with suffixes X / Y (no Z)
TP reference: 1 / 2 single-phase, 3 / 4 three-phase, 5 two-channel, 8 / 9 new platform (still use the single-phase or three-phase key names above).
Meaning: V voltage, I current, P power, PF power factor, F frequency, FE forward energy, RE reverse energy. A trailing X/Y/Z denotes the phase or channel.
Units: voltage V, current A, power kW (not W), energy kWh, frequency Hz. The strings contain digits only, no unit. Approximate decimals: voltage 1, current / power 3, power factor / frequency / energy 2.
Single-phase read-back shape (values are illustrative):
Three-phase read-back (real SDM01_3PN, TP is 4):
The values are consistent with each other: about 226 V, about 7.2 A per phase and about 1.63 kW per phase (226 × 7.2 ≈ 1.63 kW), which you can use as a unit sanity check.
6. Business error codes
On failure the notification or the read characteristic is JSON: ok=false, an integer code and an English msg. Success packets have no code.
For configuration failures the BLE code = 1000 + sub-code, so some numbers overlap with fixed codes (especially 1002–1005). Rely on msg; use code only as a hint.
code
msg
Meaning / action
1014
functionMap error
Illegal or over-limit combination of communication features
1015
unknow cmd
Unknown command, or this model does not have it (the msg is spelled this way, compare it verbatim)
1018
Error wifi ssid/pass required!
SSID or password missing
1019
Error wifi length!
Wi-Fi parameter too long
1021
Error mqtt data empty!
MQTT data is empty
1024
UDP full
UDP target list full, or the IP / port is invalid
1025
UDP not found
The UDP target to delete does not exist
1027
Error name length!
Display name too long
1043
scan busy
A scan is in progress, try later
1044
scan not ready
Result not ready, wait 2–3 s and fetch again
Channel gate / handshake / envelope errors are in plaintext doc Section 8 and secured doc Section 8. Less common codes: Appendix A.
6.1 Cases without a code
msg is illegal cmd / unsupported
this model does not have the command
a notification is not valid JSON
log and ignore, do not crash; suspect a too-small MTU
Appendix A Less common error codes
The BLE code = 1000 + sub-code. Most integrators will not need these.
code
msg
Meaning
1006
null
Not the matching model, no such data
1016
Timer not found
Timer does not exist
1017
Invalid timer
Invalid timer parameters
1020
Error wifi reset in progress
Wi-Fi reset conflict
1022
Error length!
MQTT or other field too long
1023
cafile error
Certificate flow error
1028
mda format error
Register extension format error
1029
mda failed
Register extension failed
1030
minvert data format error
Invert configuration format error
1031
minvert save failed
Saving invert configuration failed
1032
minvert data length error
Invert configuration length error
1033
minvert data error
Invert configuration data error
1034
minvert missing data
Invert configuration data missing
1035
bleota no data
BLE OTA: no data
1036
bleota err param
BLE OTA: invalid parameter
1037
bleota err state
BLE OTA: wrong state
1038
bleota err seq
Packet sequence not continuous
1039
bleota err crc
CRC failure
1040
bleota err write
Partition write failed
1041
bleota err size
Firmware too large
1042
bleota err unknown
BLE OTA: unknown error
Appendix B functionMap bits
d.functionMap is a 16-bit integer. Bit n is on when functionMap & (1<<n) is non-zero.
15
Modbus TCP
14
TLS (usually together with Modbus)
13
UDP
11
WebSocket
10
WebSocket TLS
9
MQTT
7
HTTP :80
5
LoRaWAN
others
Reserved, ignore them
Examples: 128 = HTTP only; HTTP + MQTT = 128 + 512 = 640; 32896 = Modbus TCP + HTTP.
Appendix C model short keys
WN
Wi-Fi SSID
WPN
Device display name
MH
MQTT host (empty = not configured)
MF
Whether MQTT is connected (boolean)
MP
MQTT port (0 = not configured)
MC
MQTT ClientId
MI
MQTT report interval, in milliseconds
MS
Whether MQTT uses TLS
LSM
Weak-signal mode, 0 / 1
UI
UDP report interval, in milliseconds
WI
WebSocket push interval, in milliseconds (models without WebSocket do not have this key)
TS
Modbus TLS multiplexing state 0–5 (some models only)
MAD
485: address / baud rate / parity, e.g. 5 / 9600 / N81
Last updated